How to split a building with mixed usage
Purpose
Section titled “Purpose”Model a building that has more than one usage, e.g. a property with both housing and shops.
Prerequisites
Section titled “Prerequisites”You’re on Building and operation, in the Usages table. The table always has at least one usage.
- Click Add usage for each extra use in the building: a new row is created in the table for each one.
- Give each usage a name, and choose Building type and BBR category.
- Fill in the areas for each usage: Heated, Storey area and optionally Heated basement, Garage and Balcony. If a usage is unheated, e.g. parking, write 0 as its heated floor area.
- Under Energy consumption in operation the table now has a Usage column: choose for each energy source whether it applies to the whole building or one specific usage.
Result
Section titled “Result”The limit value is calculated as an area-weighted average of the usages’ own limit values (BR § 298(4)), weighted by each usage’s reference area (§ 297(5)). An unheated usage therefore counts towards the weight. Above the table stands the calculation for the weighted limit value, and the Name and share column shows each usage’s share.
Trap: if heated floor area or storey area is missing on even one usage, the limit value cannot be calculated at all, not just for that usage, but for the whole building. A heated floor area of 0 is not missing, but an empty field is.