Skip to content
Support
Machine-translated from Danish

How to split a building with mixed usage

Model a building that has more than one usage, e.g. a property with both housing and shops.

You’re on Building and operation, in the Usages table.

  1. Click Add usage for each actual use in the building: a new row is created in the table for each one.
  2. Fill in heated floor area and BBR category for each individual usage.

The limit value is calculated as an area-weighted limit across the usages (BR § 298(4)). The weight is each usage’s reference area (BR § 297(5)), not its heated floor area. An unheated usage, for example parking, therefore counts towards the weight.

The heated floor area is still used: it decides which area bracket the building falls into, and it is the basis for operational energy (B6) and standard values.

Trap: if heated floor area or gross floor area is missing on even one usage, the area-weighted limit value can’t be calculated at all, not just for that usage, but for the whole building.