Building and operation
The building’s basic data, uses, calculation settings and operational energy. See the full walkthrough in Describe the building under Building and operation.

The key-figure band
Section titled “The key-figure band”At the top of the page, under the page title, stand four key figures:
| Key figure | Meaning |
|---|---|
| Climate impact against BR requirement · § 298 | The project’s figure against the limit value, with Compliant or Exceeded. If a use lacks a BBR category, no figure is shown |
| Reference area · § 297(5) | The server’s reference area, with the calculation (or the figure per use for mixed use) |
| Area in the operation calculation · B6 | The area the operational energy is calculated from, with the calculation “heated floor area H + 0.5 × heated basement K” |
| Calculation | Calculation mode and assessment period, and a module strip showing which modules the mode counts in. Click the strip to open the module diagram |
One row per use. A project always has at least one, and for mixed use more are added with Add use. If you hover a column heading, the app explains the column.
| Column | Meaning |
|---|---|
| Name and share | The use’s name. For mixed use also its share of the area-weighted limit value |
| Building type | Affects default values for technical installations (drain, water, and heating, ventilation and cooling) |
| BBR category | BBR use code: used to choose limit values |
| Heated | Heated floor area: the base area for operational energy (B6), default values and DGNB reference factors. Includes heated basements within the storey area per BR § 455. Write 0 for an unheated use |
| Heated basement | Only the part of the heated basement that falls outside the storey area. The operation calculation (B6) adds 50% of it, the default values 100%. Do not add 50% yourself |
| Storey area | The building’s storey area per BR § 455, incl. basement and safety-room area. Counts 100% in the reference area |
| Garage | Conservatories and balcony enclosures, and integrated garages for detached houses, terraced houses and similar (per § 297(5)). Counts 50% in the reference area |
| Balcony | External ramps, stairs, balconies, integrated carports, sheds etc. Counts 25% in the reference area. Covered terraces and exploited roof surfaces do not count |
| Users | Number of users: documentation, not part of the calculation |
| Operation (B6) | Calculated: the area in the operation calculation for the use |
| Reference area | Calculated: storey area + garage × 0.5 + balcony × 0.25 |
For mixed use, the calculation for the weighted limit value stands above the table. The weight is each use’s reference area (BR § 298(4)), so an unheated use counts too. In the Total row, Heated, Operation (B6) and Reference area show their calculation as a tooltip.
Reference area and heated floor area are two different figures with two different purposes; see the background article about the two areas for details.
Below the table stand warnings if something is missing: BBR category, building type, heated floor area or storey area. If one of the two areas is missing on just one use, the limit value cannot be calculated.
Energy consumption in operation
Section titled “Energy consumption in operation”| Column | Meaning |
|---|---|
| Energy source | Energy source from the library, e.g. electricity or district heating, added with Add energy source |
| Description | Free comment, e.g. where the figure comes from |
| Use | Only for mixed use: whether the energy source applies to the whole building or one use |
| Consumption | kWh/m²/year: multiplied by the area in the operation calculation (B6) and the source’s reference values |
| Supplement | The difference between two energy frame calculations (with and without supplement-giving conditions) |
| Exported | Only on electricity rows: own production, e.g. from solar cells, which enters as negative consumption in module D |
Below the table stand the net operational consumption and the average contribution to B6 over the period.
Default values for technical installations
Section titled “Default values for technical installations”One row per kind: drain, water, and heating, ventilation and cooling. If you tick a kind, the project uses the default value for it, and the category’s own content is skipped under Special conditions. The quantity is factor × (heated floor area + 100% heated basement) for the uses the row covers. The table shows the building product in the building model, the quantity, the GWP contribution and which categories the default value replaces. If one of the building types has no default value for the kind, the table shows a warning: that use gets a zero contribution.
Calculation
Section titled “Calculation”| Field | Meaning |
|---|---|
| Calculation mode | Controls which life cycle modules are included. BR18 (2025): A1-3, A4-5, B4, B6, C3-4, D. A switch creates a new version |
| Construction process (A4-A5) documented in another tool | Only in BR18 (2025): takes A4 and A5 out of the calculation, see How to document the construction process in another tool |
| Year of commissioning | The start year: operational energy is calculated from the year after. If missing, 2025 is used |
| Assessment period | The number of years the assessment covers, typically 50. Locked for some calculation modes. If missing, 50 years are used |
Building
Section titled “Building”| Field | Meaning |
|---|---|
| Classification | The classification system (e.g. LCAbyg 5) that structures the building model. A switch asks for confirmation and shows how many constructions will end up outside the calculation, see How to change classification |
| Storeys above/below | Documentation: not part of the calculation |
| Further description | Free comment, imported from .lb5 |