Building and operation
The building’s core data, usages, calculation settings and operational energy. See the full walkthrough in Describe the building under Building and operation.
Building
Section titled “Building”| Field | Meaning |
|---|---|
| Classification | The classification system (e.g. LCAbyg 5) that structures the building model. Changing it is destructive — all constructions lose their classification |
| Storeys above/below ground | Documentation — not part of the calculation |
| Additional description | Free comment, imported from .lb5 |
Usages
Section titled “Usages”A building can have multiple usages for mixed-use buildings. Each usage has its own heated floor area and its own BBR category.
Calculation
Section titled “Calculation”| Field | Meaning |
|---|---|
| Building type | Affects default values for installations (drainage, water, installations) |
| Building category (BBR) | BBR usage code — used to select limit values |
| Calculation mode | Controls which life cycle modules are included. BR25: A1-3, A4-5, B4, B6, C3-4, D |
| Assessment period | Number of years the assessment covers — typically 50 years |
| Gross floor area (100%) | The building’s floor area per BR § 455, incl. basement and shelter room area |
| Carports, sheds, balconies etc. (25%) | See box below |
| Heated floor area | Multiplier for energy consumption, default values and DGNB reference factors |
| Heated basement area | Gets a 50% addition in the BR calculation (energy frame convention) |
| Year of occupancy | The start year — energy consumption is calculated from the year after |
Reference area (gross floor area + the two weighted categories) and heated floor area are two different numbers with two different purposes — see the background article on the two areas for details. Covered terraces and used roof areas do not count in the 25% category.
Energy consumption
Section titled “Energy consumption”| Field | Meaning |
|---|---|
| Supply source | Energy source from the library, e.g. electricity or district heating |
| Consumption | kWh/m²/year — multiplied by heated floor area and the source’s reference values |
| Supplement (electricity/heat) | The difference between two energy frame calculations — with and without the supplement-triggering conditions |
| Own production | E.g. solar panels — counted as negative consumption in module D |
Default values
Section titled “Default values”Default values for technical installations, used when the project has no more specific data of its own. A missing default value results in a 0 contribution, with no warning that stops you.