Skip to content
Support
Machine-translated from Danish

Building and operation

The building’s core data, usages, calculation settings and operational energy. See the full walkthrough in Describe the building under Building and operation.

FieldMeaning
ClassificationThe classification system (e.g. LCAbyg 5) that structures the building model. On a change, constructions keep their old category but sit outside the new classification and do not count until they are classified
Storeys above/below groundDocumentation — not part of the calculation
Additional descriptionFree comment, imported from .lb5

A building can have multiple usages for mixed-use buildings. Each usage has its own heated floor area and its own BBR category.

FieldMeaning
Building typeAffects default values for installations (drainage, water, installations)
Building category (BBR)BBR usage code — used to select limit values
Calculation modeControls which life cycle modules are included. BR18 (2025): A1-3, A4-5, B4, B6, C3-4, D
Assessment periodNumber of years the assessment covers — typically 50 years
Gross floor area (100%)The building’s floor area per BR § 455, incl. basement and shelter room area
Carports, sheds, balconies etc. (25%)See box below
Heated floor areaThe base area for operational energy (B6), default values and DGNB reference factors. Includes heated basements that fall within the floor area per BR § 455
Heated basement areaOnly the part of the heated basement that falls outside the floor area. The operational calculation (B6) adds 50% of it, the default values add 100%. Don’t add the 50% yourself
Year of occupancyThe start year — energy consumption is calculated from the year after

Reference area (gross floor area + the two weighted categories) and heated floor area are two different numbers with two different purposes — see the background article on the two areas for details. Covered terraces and used roof areas do not count in the 25% category.

The card Area in the operational calculation · B6 shows the server’s figure for the area the operational energy is calculated from, with the arithmetic “heated floor area H + 0.5 × heated basement K”. For mixed use it is distributed by each usage’s B6 area. The total cells for Heated and Reference area in the usage table likewise show their arithmetic as a tooltip.

FieldMeaning
Supply sourceEnergy source from the library, e.g. electricity or district heating
ConsumptionkWh/m²/year — multiplied by heated floor area and the source’s reference values
Supplement (electricity/heat)The difference between two energy frame calculations — with and without the supplement-triggering conditions
Own productionE.g. solar panels — counted as negative consumption in module D

Default values for technical installations, used when the project has no more specific data of its own. A missing default value results in a 0 contribution, with no warning that stops you.