Skip to content
Support
Machine-translated from Danish

Library

The collection of reusable constructions and building products. Opened via Library in the top menu.

ElementMeaning
TypeOfficial (blue), Organization (green) or Personal (purple), see the access rules below
OwnerWho owns the library
Publishing statusPublished or Draft
Calculation modesWhich calculation modes the library is compatible with

Requires a name and an organization to own the library. The dialog shows publishing and calculation modes filled in up front: organization and personal libraries are created published with all active calculation modes, official ones are not.

The tabs reflect what the library actually contains: a Constructions tab if the library has constructions, and one tab per building product type the library actually has building products of (Building material, Energy, Fuel, Transport method, Transport standard, Waste). An empty library shows no tabs.

Each tab has two views: Overview (card view) and Data (table view).

The building product’s header and classification

Section titled “The building product’s header and classification”

At the top of a building product is a header with the name and a row of badges, in both Overview and Data, including owner, version, ID and the EPD’s own classification. The same header is shown on the building product when you choose it with Insert from library in the building model.

  • ID is the EPD’s registration number, which the EPD is usually referred to by. You can select and copy it. A building product without an EPD number has no ID.
  • The classification shows the lowest level of the category the EPD is published under. If it says Corrected at import next to it, an error in the EPD file was corrected when it was brought in. The category is still the one the programme operator published.

In Data, the Classification field is under Details, right after Material category. It shows the system’s name and the whole chain of categories, for example “ÖKOBAU.DAT: Mineral building products > Aggregates > Sand and gravel”. The field cannot be edited. Click Show how the category was published to see who published the category, how it appears in the EPD file, and what, if anything, was corrected. If the EPD has no classification, it says No classification.

The classification is the EPD’s own and is not the same as Material category, which is LCAbyg’s category and is used in, for example, the Materials chart.

The creation guide has up to five steps: Type → Details (name, unit, classification) → Composition (constructions only) → Emissions (modules and indicators) → Source (version, EPD source). Steps 3 and 4 can be skipped and finished later from the product’s detail page.

Building product types and what they are used for:

TypeUsed for
Building materialThe building model: real life cycle modules (A1-A3, C, D) and service life
EnergyElectricity, heat, water. Used in Operation (B6), construction site (A5) and transport (A4)
FuelDiesel, petrol, HVO etc. Used on the construction site and in detailed transport
Transport methodLorry, train, ship, plane: factor per kg·km, detailed transport
Transport standardStandard transport scenario: factor per kg of building product
WasteWaste fractions on the construction site: modules A1-A3 + C3 + C4

Emissions are entered either as one fixed factor or factor per year (interpolated linearly between years; outside the range the nearest year is used).

Constructions are built from sub-constructions and/or building products, each with its own quantity.

A gen_dk ZIP file with generic Danish reference data can be imported in one go via the Import function. The content (constructions, products, modules and energy supplies) is added to the library as ordinary library content.

The same Import function has a short Import element card that takes an .lb5elm element file or a .json file. The element’s constructions are added with their building products and modules, and you choose whether the outermost building element is imported as a group (recommended) or as one combining construction. See How to import an element file into a library.

A library’s settings cover name, type, owner, version, publishing status and calculation modes. A library only appears in a project’s library picker if it is both published and has at least one calculation mode selected that matches the project. Choose the calculation mode at the same time as you publish, see How to publish a library.

TypeCan seeCan edit
OfficialEveryone, when publishedMaintained centrally
OrganizationAll members of the owning organization (also as a draft)Only organization owners
PersonalThe creator always. Colleagues in the organization once the library is published (then it can also be used in the company’s projects)Only the creator

An unpublished (draft) official library is hidden from everyone. An organization library in draft is still seen by the organization’s members and is marked with a Draft badge, and a personal library in draft is seen only by its creator. Whatever the type, a library in draft cannot be used in projects.

If the owner of a personal library leaves the organization, is deleted from it or deletes their account, the library transfers to the organization as an organization library, which the organization’s owner can edit. Projects using the library notice no change.