Limit values
Comparison against the limit values for the project’s calculation mode. Values are normalized per m²/year (reference area × assessment period).

Two separate assessments
Section titled “Two separate assessments”| Section | Content |
|---|---|
| Building | The modules A1-A3, B4, B6, C3, C4. The chart has one bar for §297 and one for §298(7-8) showing the value after deductions for energy supplements and special conditions (the light fields): that is the one compared against the limit value. Above the chart stand the reference area, the B6 area and the assessment period |
| Construction process A4+A5 (§298(5)) | Transport to construction site (A4) and the construction site’s consumption (A5) have their own limit value, separate from the building’s |
By each chart the verdict stands as a badge: Within the limit or Over the limit, with the project’s figure and the limit, e.g. “7.4 / 10.5”. If no statutory requirement applies to the building, e.g. because it falls outside the limit value’s area or category restriction, it says No statutory requirement instead.
Below each chart stands a table per limit value, e.g. Statutory requirement (BR18 (2025)) and Voluntary class (BR18 (2025)), with indicator, module, project value, limit, unit and status.
| Status | Meaning |
|---|---|
| OK | The project is below the limit value |
| Over | The project exceeds the limit value |
| No data | The project has no data for the indicator |
| Missing area | The reference area is missing, so the value cannot be normalized |
If the project has mixed use, the weighted calculation of the limit value stands at the top of the page, e.g. “17% × 8.0 + 83% × 7.5 = 7.6”. The weight is each use’s reference area.
If the construction process is set to be documented in another tool, then instead of an assessment of A4+A5, the page says that it is documented in another tool and not assessed here, see How to document the construction process in another tool.
The charts can be copied as an image or downloaded as SVG, see How to copy a graph to Word or PowerPoint.
Error messages to know
Section titled “Error messages to know”When one of these messages stands on the page, there is no verdict.
| Message | Cause |
|---|---|
| Missing BBR category | One or more uses lack a BBR category: the limit value depends on it and cannot be determined until every use has chosen one |
| Missing areas | One or more uses lack heated floor area or storey area. Write 0 as the heated floor area if the use is unheated |
| Ambiguous limit values, or “The limit value cannot be determined” | Several limit values in LCAbyg’s catalogue apply to the building at the same time: an error in the catalogue, not in the project. Contact LCAbyg |
| “No limit values are defined for the project’s calculation mode” | No limit is defined for the selected mode |