Skip to content
Support
Machine-translated from Danish

How to fill in the building's areas

Fill in the areas that make up the building’s reference area, the denominator in the result (kg CO₂-eq/m²/year).

You’re on Building and operation, in the Usages table.

The Usages table with the area columns

  1. Fill in the Storey area (m² · 100%) column: the building’s storey area per BR § 455, incl. basement and shelter room area. The field must be greater than 0.
  2. Fill in the Garage (m² · 50%) column: conservatories and balcony enclosures, and integrated garages for detached houses, terraced houses and similar (per § 297(5)).
  3. Fill in the Balcony (m² · 25%) column: exterior ramps, stairs, fire escapes, balconies and balcony access; integrated carports, sheds, canopies and outbuildings; and walk-on ceilings. Covered terraces and used roof areas do not count here (per § 297(5)).

If you hover a column heading, the app shows what belongs in the column. 4. Fill in Heated floor area: a separate area, in the same table, see that page for details.

The reference area is calculated automatically as the sum of storey area (factor 1.0), garage (factor 0.5) and balcony (factor 0.25), and is used as the denominator in all m²-normalized results. The Reference area column shows the figure per usage, and the Total row shows the calculation when you hover the sum. For mixed use, the reference area is also the weight each usage gets in the area-weighted limit value.

Reference area=1.0 × storey area + 0.5 × garage + 0.25 × balcony

If the storey area is missing on a usage, the limit value cannot be calculated until it is filled in.