Mixed use and the area-weighted limit value (§298(4))
How the limit value is calculated for a building with several use categories.
If a building has several usages, e.g. homes on the upper floors and shops on the ground floor, each usage has its own limit value, because the limit value depends on the BBR category. BR § 298(4) collects them into one limit value for the whole building: an area-weighted average of the usages’ limit values.
How it is calculated
Section titled “How it is calculated”- Each usage gets its own limit value from its BBR category. If the limit depends on the building’s size, the usage’s heated floor area is used to find the right one.
- Each usage weighs with its reference area (BR § 297(5)): storey area + garage × 0.5 + balcony etc. × 0.25. The share is the usage’s reference area divided by the building’s total.
- The weighted limit value is the sum of share × limit value for all usages, rounded to one decimal.
Example: if 17% of the reference area lies in a usage with the limit value 8.0, and 83% in a usage with the limit value 7.5, the building’s limit value is 0.17 × 8.0 + 0.83 × 7.5 = 7.58, rounded to 7.6 kg CO₂-eq/m²/year.
Each limit value is weighted separately, so the statutory requirement and a voluntary class each get their own weighted value.
Why the reference area
Section titled “Why the reference area”The weight is the reference area and not the heated floor area. An unheated usage, e.g. parking, therefore counts towards the weight with its full reference area, even though its heated floor area is 0.
Until September 2026, LCAbyg weighted by the heated floor area. If a project has an unheated usage, the limit value may therefore be different when the version is calculated again.
What the calculation requires
Section titled “What the calculation requires”For LCAbyg to calculate a limit value, every usage must have:
- a BBR category
- a heated floor area: 0 is valid for an unheated usage, an empty field is not
- a storey area greater than 0.
If one of them is missing on just one usage, no limit value is calculated and therefore no verdict for the whole building. That also applies when the building has only one usage.
Where you see the calculation
Section titled “Where you see the calculation”- Building and operation: above the Usages table stands the calculation for the weighted limit value, and the Name and share column shows each usage’s share.
- Limit values: the weighted calculation stands at the top of the page, e.g. “17% × 8.0 + 83% × 7.5 = 7.6”.
- The report: a table with usage, BBR category, reference area, share, limit value and contribution.