Skip to content
Support
Machine-translated from Danish

How to specify heated floor area

Specify the area used as a multiplier for energy consumption, default values and DGNB energy reference factors, separate from the reference area.

You’re on Building and operation, in the Usages table.

  1. Fill in the Heated column for the usage. If the usage is unheated, e.g. a parking basement, write 0: an empty field counts as missing, and then the limit value cannot be calculated.
  2. If the building has a heated basement area that does not lie within the storey area, also fill in the Heated basement column. The operation calculation (B6) automatically adds 50% of it in the BR calculation (energy frame convention), so do not add 50% yourself.
  3. If the building has mixed usage, the area is already specified per usage, because each usage is its own row in the table, see How to split a building with mixed usage.

Energy consumption (kWh/m²/year) is multiplied by the area in the operation calculation (B6): heated floor area plus 50% of the heated basement in the BR calculation. The app calculates it for you and shows it in the Operation (B6) column per usage and in the key-figure band at the top of the page.

Area in the operation calculation (B6)=heated floor area + 0.5 × heated basement

Heated floor area is not part of the reference area, and the reference area is not part of the heated floor area. The two numbers each have their own purpose and both need to be filled in correctly.